Ecr Tests; Display Tests; Fig. 5.1 The Segment Lcd Area Division; Tab. 5.1 The Ecr Euro-500Tx Handy Tests - ELCOM Euro-500 Handy Series Service Manual

Table of Contents

Advertisement

Euro-500TX Handy
The Euro-500TX Handy ECR tests allow quick diagnostics and checking
of functionality of the ECR. The tests range from test of display elements,
keyboard test, through circuit tests to many other components.
Test #
701-716
Individual test launch procedure for Euro-500TX Handy:
1. Press numerical key 4 and key [Mode] and the ECR enters the program-
ming mode.
2. Enter the number of the test you want to perform.
3. Press the [Multiply] key.

5.1 Display tests

The display test gradually display the displayable characters on both dis-
plays.
Procedure:
1. Switch the ECR into programming mode.
2. Enter '100' using numerical keys.
3. Press the [Multiply] key.
Testing procedure for the segment LCD:
The numbers '8' and periods '.' start displaying on the LCD from right to left
and, simultaneously, the arrows in the left part of the display will begin to
blink from top to bottom.
50
Service manual

5 ECR tests

Description
100
Display tests
200
Printing test
201
Thermal head postion test
202
Paper presence sensor test
300
Keyboard test 1
310
Keyboard test 2
501
RS-232 serial interface test for PC
502
RS-232 serial interface test for scanner and scales
503
External PC keyboard interface test
600
ECR drawer test
700
FM data reading tests (FM versions only)
FM data reading tests in 8 kb cunks (FM versions only)
720
FM data writing test (FM versions only)
730
FM working voltages test (FM versions only)
740
FM control signals test 1 (FM versions only)
750
FM control signals test 2 (FM versions only)
800
EPROM checksum test
900
Accumulator tests
910
VCC1 power supply test

Tab. 5.1 The ECR Euro-500TX Handy tests

Arrows
Numerical part
© Elcom, s. r. o.
n A
o ... w
l
n A
opp
l
Fig. 5.1 The segment LCD area
division

Advertisement

Table of Contents
loading

This manual is also suitable for:

Euro-500tx handy

Table of Contents