Ecr Drawer Test; Fiscal Memory Tests; Fm Data Reading Tests; Tab. 5.2 Fm Partitioning For Individual Tests - ELCOM Euro-500 Handy Series Service Manual

Table of Contents

Advertisement

Euro-500TX Handy

5.5 ECR drawer test

This test allows the diagnostics of the drawer opening circuits. The connec-
tion of a drawer is described in the chapter 4.13.
Note: External power supply has to be connected.
Procedure:
1. Switch the ECR into programming mode.
2. Enter '600' using numerical keys.
3. Press the [Multiply] key.
Testing procedure:
1. The drawer-opening signal is generated in short intervals.
2. If the circuits are functional, the ECR drawer opens.
If any errors in opening of the drawer appear, consult chapter 6.8 for guid-
ance.

5.6 Fiscal memory tests

These tests allow functionality testing for FM circuits that provide reading,
verification, and writing of data into FM.

5.6.1 FM data reading tests

Data reading tests allow the checking of the data written in FM. Both read-
ing the entire FM and reading FM in 8 kB chunks is possible using the ECR
tests.
Entire FM data reading test
Procedure:
1. Switch the ECR into programming mode.
2. Enter '700' using numerical keys.
3. Press the [Multiply] key.
Testing procedure:
1. The data is read from the FM.
2. All data read from the FM is printed on the ECR printer.
FM data reading test in 8 kB chunks
Procedure:
1. Switch the ECR into programming mode.
2. Enter '701'–'716' using numerical keys.
3. Press the [Multiply] key.
Testing procedure:
1. The data is read from the specified FM segment.
2. All data read from given segment of the fiscal memory is printed on the
ECR printer.
Test #
Address space
701
00000-01FFF
702
02000-03FFF
703
04000-05FFF
704
06000-07FFF
705
08000-09FFF
706
0A000-0BFFF
707
0C000-0DFFF
708
0E000-0FFFF

Tab. 5.2 FM partitioning for individual tests

Service manual
Test #
Address space
709
10000-11FFF
710
02000-03FFF
711
14000-15FFF
712
16000-17FFF
713
18000-19FFF
714
1A000-1BFFF
715
1C000-1DFFF
716
1E000-1FFFF
© Elcom, s. r. o.
n A
xpp
l
Successful test summary:
** TEST **
600
n A
mpp
l
n A
mpo – ox
l
Successful test summary:
** TEST **
700
Summaries of successful tests:
** TEST **
701 (701-716)
55