Euro-500TX Handy
The connectors PCB connexion
The external devices connectors are fitted onto the connectors PCB that is connected to the ECR. This
PCB also collects all the vital signals and transfers them to the main PCB using two cables.
External adapter
– pole
External adapter
+ pole
REAR1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
MOLEX53047-1510
REAR2
2
1
AVA 5400-2P-S
26
Service manual
GND
PC
PC
GND
RxD
TxD
1
PC
Fig. 2.36 Individual ECR connectors pin connexion
GND
PCTxD
PC RxD
GND
SCLTxD
SCLRxD
SCRRxD
GND
EKB-DATA
EKB-CLKA
DRW-
GND
VCC
GND
ADP+
ADP-
Fig. 2.37 Connector PCB connexion
Scales
Scanner
Scales
RxD
RxD
TxD
+5 V
Drawer
+ pole
1
SCR/SCL
Drawer
EKB-DATA
GND
VCC
EKB-CLKA
DRW-
ADP+
VC C
SCLTxD
SCRRxD
SCLRxD
GND
PCTxD
PCRxD
GND
ADP+
ADP-
© Elcom, s. r. o.
Drawer
– pole
Clock
NC
1
Vcc
NC
Keyb
GND Data
EXTKEYB
1
2
3
4
5
6
Minidin 6 pin
DRAWER
1
2
3
4
Modular 4 pin
SCR&SCL
1
2
3
4
5
6
Modular 6 pin
PC
1
2
3
4
5
6
Modular 6 pin
POWER
1
2
3
DS 210 D (Bond tact)