Connecting To The Network; Install The Server Blade - HPE ProLiant BL460c Gen10 User Manual

Hide thumbs Also See for ProLiant BL460c Gen10:
Table of Contents

Advertisement

Server blade
signal
FlexibleLOM
Mezzanine 1
Mezzanine 2

Connecting to the network

To connect the BladeSystem to a network, each enclosure must be configured with network interconnect
devices to manage signals between the server blades and the external network.
Two types of interconnect modules are available for BladeSystem c-Class enclosures:
Pass-Thru modules
Switch modules
For more information about interconnect module options, see the Hewlett Packard Enterprise website.
IMPORTANT: To connect to a network with a Pass-Thru module, always connect the Pass-Thru
module to a network device that supports Gigabit or 10 Gb speed, depending on the corresponding
Pass-Thru model.

Install the server blade

CAUTION: To prevent improper cooling and thermal damage, do not operate the server blade or the
enclosure unless all device bays are populated with either a component or a blank.
CAUTION: Failure to install the divider in a quadrant when installing half-height blades can result in
damage to the connectors on the server blade.
42
Setup
Interconnect bay
Interconnect bay
number
label
1
2
3 and 4
Notes
Four-port cards connect to bay 2.
Four-port cards
Ports 1 and 3 connect to bay 3.
Ports 2 and 4 connect to bay 4.