Installing The M.2 Ssds - HPE ProLiant BL460c Gen10 User Manual

Hide thumbs Also See for ProLiant BL460c Gen10:
Table of Contents

Advertisement

11. Install the access panel on page 23.
12. Install the server blade on page 42.
13. Power up the server blade on page 21.

Installing the M.2 SSDs

Prerequisites
A No. 1 Phillips screwdriver is required to perform this procedure.
Procedure
1.
Power down the server blade on page 21.
2.
Remove the server blade on page 22.
3.
Place the server blade on a flat, level work surface.
4.
Remove the access panel on page 22.
5.
Remove the left DIMM baffle (Remove the DIMM baffles on page 23).
6.
Verify that the PEM nuts and rubber stoppers are in the correct location to support the length of the
M.2 SSDs being installed. Relocate the PEM nuts and rubber stoppers, if necessary.
For more information, see Relocate the PEM nut and rubber stopper on page 28.
7.
Remove the screw with a No. 1 Phillips screwdriver, and then install the M.2 SSD.
Hardware options installation
59

Advertisement

Table of Contents
loading

Table of Contents