Drive Numbering; Hot-Plug Drive Led Definitions - HPE ProLiant BL460c Gen10 User Manual

Hide thumbs Also See for ProLiant BL460c Gen10:
Table of Contents

Advertisement

Drive numbering

Depending on the configuration, this server blade can support hard drives, SSDs, NVMe SSDs, and uFF
drives (supported in a SFF Flash Adapter) in the drive bays. Depending on the device installed, the bay
number might be different.
Item Hard drive/SSD bay
numbering
1
1
2
2

Hot-plug drive LED definitions

Item LED
1
Locate
2
Activity
ring
3
Do not
remove
4
Drive
status
1
uFF drive bay
numbering
1 and 101
2 and 102
Status
Definition
Solid blue
The drive is being identified by a host application.
Flashing blue
The drive carrier firmware is being updated or requires an update.
Rotating green
Drive activity
Off
No drive activity
Solid white
Do not remove the drive. Removing the drive causes one or more of
the logical drives to fail.
Off
Removing the drive does not cause a logical drive to fail.
Solid green
The drive is a member of one or more logical drives.
2
NVMe drive bay numbering
1
2
Table Continued
Component identification
9

Advertisement

Table of Contents
loading

Table of Contents