Installing The Hpe Smart Storage Battery - HPE ProLiant BL460c Gen10 User Manual

Hide thumbs Also See for ProLiant BL460c Gen10:
Table of Contents

Advertisement

Installing the HPE Smart Storage Battery

WARNING: The server blade may contain internal replaceable battery cells or battery packs. A risk
of fire, burns, or explosions exists if the battery pack is not properly handled. To reduce the risk of
personal injury:
Do not attempt to recharge the battery outside of the installed application.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of the battery in fire or
water.
Replace only with the Hewlett Packard Enterprise spare battery designated for this product.
Dispose of used batteries according to the manufacturer's instructions and local disposal
requirements.
For battery holders (for example, coin cells), observe the correct polarity when changing the
battery/cell. A danger of explosion exists if the battery is installed incorrectly.
System ROM and firmware messages may display "energy pack" in place of "Smart Storage Battery."
Energy pack refers to both HPE Smart Storage Batteries and HPE Smart Storage Hybrid Capacitors.
Procedure
1.
Power down the server blade on page 21.
2.
Remove the server blade on page 22.
3.
Place the server blade on a flat, level work surface.
4.
Remove the access panel on page 22.
5.
If installed, remove the direct connect SATA cable (Remove the direct connect SATA cable on
page 31).
6.
If installed, remove the internal USB drive.
To locate the internal USB connector, see System board components on page 13.
7.
Remove the right DIMM baffle (Remove the DIMM baffles on page 23).
8.
Install the HPE Smart Storage Battery on the right DIMM baffle.
Hardware options installation
51