:SBUS<n>:MANChester:TSIZe
Command Syntax
:SBUS<n>:MANChester:TSIZe <#bits>
<#bits> ::= from 0-32, in NR1 format
When the display format is WORD (see :SBUS<n>:MANChester:DISPlay), the
:SBUS<n>:MANChester:TSIZe command specifies the number of bits in the trailer
field of your Manchester protocol definition.
Query Syntax
:SBUS<n>:MANChester:TSIZe?
The :SBUS<n>:MANChester:TSIZe? query returns the number of trailer field bits
setting.
Return Format
<#bits><NL>
<#bits> ::= from 0-32, in NR1 format
See Also
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
(see
page
1354)
":SBUS<n>:MANChester:DISPlay"
":SBUS<n>:MANChester:DSIZe"
":SBUS<n>:MANChester:HSIZe"
":SBUS<n>:MANChester:SSIZe"
":SBUS<n>:MANChester:WSIZe"
on page 833
on page 834
on page 835
on page 839
on page 846