SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
TO AVOID SERIOUS INJURY, DO NOT OPERATE MACHINE IF ANY CONTROL
LEVERS OR SWITCHES CONTROLLING PLATFORM MOVEMENT DO NOT
RETURN TO THE OFF POSITION WHEN RELEASED.
3.1

GROUND CONTROL STATION

See Figure 3-2. Ground Control Station
FOR PROLONGED SHUTDOWN OR WHILE PERFORMING MAINTENANCE/
REPAIRS, TURN OFF THE BATTERY DISCONNECT SWITCH.
1. Main Power Key Switch
This switch must be turned to the ON (I) position
before power is supplied to the Power/Emergency
Stop switch. When machine is not in use, the key
can be removed in the OFF (O) position.
2. Power/Emergency Stop Switch
This two-position red switch removes power from
the ground controls when pushed in. Twist the
switch clockwise to allow for machine operation at
the ground control station.
3121783
3. Platform/Ground Selector Switch
This selector switch allows the operator to control
the machine from the platform control box when
in the counter-clockwise position.
This selector switch allows the operator to control
the machine from the ground control station when
in the clockwise position.
4. Bypass Key Switch
See Section 5.4, Bypass Key for more information.
5. In the Controls menu, this button is used to switch
between machine control functions.
6. Controls machine movement in the UP or RIGHT
direction.
7. Controls machine movement in the DOWN or LEFT
direction.