SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION
Position 7
Can indicate any of the following situations:
• An emergency stop is pushed in (off ).
• A low battery. Batteries need charging
1
3
5
7
by running the gas/diesel engine or
2
4
6
8
connecting to a power source.
• Tower boom sensor is faulty.
• Main boom sensor is faulty. Boom func-
tions are cut out.
• Swing sensor is faulty.
• CANBUS communication is faulty.
• Electronic fault.
• Lithium ION - Signals an error in the
BMS - Battery Management System
• Skyguard™ sensor has be activated.
• Battery cold/heater activated system is
enabled.
• Safety by-pass activated
STOP
CAN
BUS
?
3121783
SEN.1
SEN.3
SWING
FAIL
FAIL
CARD
?
Position 8
3
5
1
7
2
4
6
8
?
!
or:
• 50 Hr. - 1st Service Interval - See Section
6 - Table 6-10 and Table 6-11, Compo-
nent Maintenance Intervals.
SERV...
• Indicates emergency lowering has been
selected.
• Lithium ION - Battery Charge Status and
Battery Charger Plugged In.
• Low Lithium charge - Machine reduced
speed, must charge Lithium system.