7. Installation

7.12 Controls, Valves, Switch Locations

1. Push Button Station "Start/Stop" w/Reset Button
Controls Box taping Cycle / Resets Controls /
Starts and Stops Drive Belts.
The Circuit Breaker is preset and requires no
further maintenance. If circuit is overloaded
and trips, unplug machine from power source:
a) Determine and correct cause of overload.
b) Reconnect machine to power source.
c) The Push Button Station is used to turn
machine On and Off . The Reset Button
is used before initial startup or for
clearing a fault condition (Figure 7-11).
Push Button Station
w/Reset Button
Figure 7-11
2. Main Air "On/Off " Valve/Pressure Regulator/
Filter/Exhaust Valve – Figure 7-14
This set of pneumatic components controls,
regulates and fi lters plant air supply to two
separate control circuits of the case sealer.
"On/Off " Valve – "On" turn to "SUP"–
"Off " turn to "EXH".
Note: See 7.12
Control Function Explanations
Mechanical Latch,
Upper Drive Assembly
"Start/Stop" Station
w/Reset Button
Main Air
"On-Off "-
Valve/
Pressure
Regulator/
Filter/
Exhaust Valve
Main
Air Pressure
Gauge
Air Pressure Regulator,
Centering Side Guides
Counter Balance Regulator
3M-Matic
7000r-7000r3 HS Pro - Type 11800
Page 27
44-0009-2152-6 / ECO# 0078045
(continued)
Start
Stop
Reset
9
1
2
8
6
Upper Drive Assembly
Note – Turning air supply "Off "
Refer to Figure 7-12 and 7-13 below to acquaint
yourself with the various components and
controls of the case sealer. Also see compo-
nent locations in Section 3 and Manual 2 for
taping head components.
Important: Always turn the air "Off "
Figure 7-12 Controls, Valves
11
Electrical
Control Box
Figure 7-13 Controls, Valves and Switches
3
10
Upper Drive
7
Pressure Gauge
automatically bleeds air pressure
from the case sealer air circuit.
when machine is not in use, when servicing
the machine, or when connecting or
disconnecting air supply lines.
and Switches
(Reverse View)
Emergency Stop Switch
Upper Drive
4
Raising Switch
5
List: Photo Sensors/
Ready Lights:
Ready Light (2)
Box Exit Sensor
Taping Head
Blade Retract
(Cut Off) Sensor
Upper/Lower
Box Present Sensor
Box Centering Sensor
12
Box Centering
Width Adjustment