Vector 8 Genset Fvae2885X*A100 Maintenance Plan - Iveco VECTOR Series Technical And Repair Manual

Industrial application
Table of Contents

Advertisement

VECTOR 8 ENGINES

VECTOR 8 GENSET FVAE2885X*A100 MAINTENANCE PLAN

PRIME POWER
Prime Power is the maximum power available at variable loads for an unlimited number of hours. The average power available
during a 24 hour operating period should not exceed 80% of the prime power between the recommended servicing intervals in
standard environmental conditions.
An overload of 10% for 1 hour for every 12 hours of operation.
STAND-BY POWER
This is the maximum power available for a period of 500 hours/year with an average load factor of 90% of the stand-by power.
No type of overload is permitted for this usage.
CONTINUOUS POWER
Contact the Iveco Motors sales organization.
Periodic Checks
First level service
Second level service
General overhaul
For special applications (heavy operating conditions, T
Periodic checks
First level service
Second level service
General overhaul
LIST OF OPERATIONS
PERIODIC CHECKS
Check oil level/top up (Urania Turbo LD)
Check coolant level/top up
Check whether air/oil/diesel filter blocked warning lights are on (if wired)
Check water in diesel prefilter warning light
Print P2D32V001E
Continuous / Prime
100 h
Hourly intervals
Time intervals
h
1000
5000
25000
10 years
>40°C) the following reduction in these intervals is required:
ambient
0%
0%
- 40%
- 40%
SECTION 3 - INDUSTRIAL APPLICATION
Hourly intervals
h
1 year
500
2 years
1000
2000
81
Stand-By
1 month
Time intervals
1 year
2 years
10 years
Base - April 2006