Clearance Data - 8 Cyl - Iveco VECTOR Series Technical And Repair Manual

Industrial application
Table of Contents

Advertisement

VECTOR 8 ENGINES

Clearance data - 8 cyl.

ρ
bar
15W40 ACEA E3
ACEA E5
NOTE
Data, features and performances are valid only if the technician fully complies with all the installation requirements
provided by Iveco Motors.
Furthermore, the use of the unit after overhaul showd conform to the original specified power and engine rev/min for
which the engine has been designed.
Print P2D32V001E
Type
Compression ratio
Max. output
kW
(HP)
rpm
Max. torque
Nm
(kgm)
rpm
Loadless engine
idling
rpm
Loadless engine
peak
rpm
Bore x stroke
3
Displacement
cm
TURBOCHARGING
Turbocharger type
LUBRICATION
Oil pressure (warm engine)
- idling
bar
- peak rpm
bar
COOLING
Water pump control
Thermostat
- start of opening
ºC
FILLING
engine sump
liters
SECTION 3 - INDUSTRIAL APPLICATION
VECTOR 8
FVAE2885
FVAE2884
X*F100
A*B201
16 : 1
560
-
(760)
-
2100
-
3200
-
(320)
-
1400÷1700
-
> 800
-
< 2300
-
145 x 152
20080
with intercooler
HOLSET HX55
Forced by gear pump, relief valve single action
oil filter
Up to 6.5
By coolant
Through an idler gear
70 ± 2
FVAE2884
FVKE2887
A*B200
A*A200
745
680
(1000)
(920)
2200
2100
3960
3200
(396)
(320)
1400÷1700
1500
600 ± 25
-
2350 ± 25
-
HOLSET
KKK-K31
HX55
4.0
80
Base - April 2006
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vector 8