Figure 73
- Fit the head water outlet pipes (1).
- Fit the seals (2), fit the elbow (3), the connecting pipes
(4) and O-rings and the thermostat casing (5).
NOTE
The new head—side gaskets have already been fitted
together with the air intake manifolds.
- Tighten all the screws to a torque of 22—27 Nm.
NOTE
To facilitate assembly, here we describe how to use
the water pipe fixing screws correctly.
6. M8x1.25x75 mm
7. M8x65 mm
8. M8x1.25x60 mm
9. M8x20 mm
10. M8x30 mm
Base - April 2006
VECTOR 8 ENGINES
103472