X220 Ttl Encoder - Siemens SINAMICS S120 Combi Equipment Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

3.3.9

X220 TTL encoder

Table 3- 12
Encoder interface X220
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Type: Sub-D socket, 15-pin; TTL encoder; max. cable length 100 m
Note
Only 5 V TTL encoders are supported.
Risk of electric shock!
Only temperature sensors that meet the safety isolation specifications contained in
EN 61800-5-1 may be connected to terminals "+Temp" and "-Temp".
If these instructions are not complied with, there is a risk of electric shock!
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
Signal name
+ Temp
Clock
Clock*
P encoder 5 V
P encoder 5 V
P sense
M encoder (M)
- Temp
M sense
R
R*
B*
B
A*
A
DANGER
S120 Combi Power Modules
3.3 Interface description
Technical specifications
Motor temperature sensing
KTY84-1C130 (KTY+)
Temperature sensor KTY84-1C130 / PTC
Clock
Inverse clock
Encoder power supply
Sense input of encoder power supply
Ground for encoder power supply
Motor temperature sensing
KTY84-1C130 (KTY+)
Temperature sensor KTY84-1C130 / PTC
Ground sense input
Reference signal R
Inverse reference signal R
Inverse incremental signal B
Incremental signal B
Inverse incremental signal A
Incremental signal A
83