Graco ProControl 1KE Plus Instructions-Parts List Manual page 87

Models for management of fluid and air
Table of Contents

Advertisement

Address
Address Description
Address
Description
Description
403150
Unused
403152
Flow Rate
maximum setpoint
limit
403154
Flow Rate
minimum setpoint
limit
403156
Atomizing Air
percentage drive
maximum
403158
Atomizing Air
percentage drive
minimum
403160
Flow Control PID
gain percentage
403162
System Idle
timeout
403164
Dose Time timeout Read/Write
403166
Job Attribute code
403168
Job trigger time
403170
Unused
403172
Unused
3A6948A
Permissions
Permissions
Permissions
Units
Units
Units
Read/Write
Read/Write
cc/min
Read/Write
cc/min
Read/Write
Percent
Read/Write
Percent
Read/Write
Percent
Read/Write
minutes
seconds 0
Read/Write
Value
ms
Read/Write
Appendix A - Modbus Variable Map
Low
Low
Low
High
High
High
0
9999
0
9999
0
0x63E667
0
0x63E667
1
100
0
99
99
0
32-bit
0
32-bit
Notes
Notes
Notes
Scaled as 1 % = 65536
Scaled as 1 % = 65536
0 = Not used
0 = Not used
87