Setup Screen 6: Pressure Transducer - Graco ProControl 1KE Plus Instructions-Parts List Manual

Models for management of fluid and air
Table of Contents

Advertisement

Setup Screen
Screen 6: 6: 6: Pressure
Setup
Setup
Screen
Use this screen to specify your pressure transducer
and set its offset and slope.
Table 11
Table
Table
11
11 Setup
Setup Screen
Setup
Screen 6 6 6
Screen
Description
Description
Description
Examples
Examples
Examples
Empty
With data
3A6948A
Pressure Transducer
Transducer
Pressure
Transducer
Key
Key
Key
Enter the screen to set or change
preferences.
Press to activate a field for editing or
to accept the highlighted selection on a
menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Select the correct pressure transducer.
(None)
• 100
100
100 psi
psi
psi
2000 psi
psi
• 2000
2000
psi
4500 psi
psi
• 4500
4500
psi
Pressure transducer slope. This number
is a constant representing millivolts
per bar. The default matches the
selected pressure transducer. Operator
adjustable. Default value is "090.000".
Set the zero offset (the reading on
the gauge when no pressure is on the
system). Default value is "00.4500".
Select units.
Exit data editing.
Move between Setup Screens, fields on
a screen, or to increment/decrement the
digits when editing number fields.
Setup Screens
47