Appendix A - Modbus Variable Map

Setup Registers

Registers
Setup
Setup
Registers
All registers are 32-bit.
Address
Address Description
Address
Description
Description
403000
Communication,
Modbus Mode
403002
Communication,
Modbus Address
403004
Communication,
Modbus Baud Rate
403006
Communication,
Modbus Parity
403008
Communication,
Modbus Stop Bits
403010
Display, Date
Format
403012
Display, Backlight
Timer
403014
Display,
Maintenance
Totalizer Alarm
Enable
403016
Display, Flow Rate
Alarm Enable
403018
Display, Flow Rate
Alarm Auto Clear
403020
Unused
403022
Pressure
Transducer Enable
403024
Units, Flow Rate
403026
Units, Pressure
403028
Units, Batch
Volume
403030
Units, Grand
Volume
403032
System,
Maintenance
Target
403034
Percentage Drive
Maximum Setpoint
84
Permissions
Permissions
Permissions
Units
Units
Units
Read/Write
Bit
Read/Write
Value
Read/Write
Value
Read/Write
Value
Read/Write
Value
Read/Write
Value
Read/Write
minutes
Read/Write
Bit
Read/Write
Bit
Read/Write
Bit
Read/Write
Bit
Read/Write
Value
Read/Write
Value
Read/Write
Value
Read/Write
Value
cc
Read/Write
Read/Write
Percent
Low
Low
Low
High
High
High
0
1
1
247
0
4
0
2
1
2
0
2
0
99
0
1
0
1
0
1
0
1
0
2
0
2
0
2
0
2
0
9999999
0
99.9
Notes
Notes
Notes
0 = Off
1 = On
0 = 9600
1 = 19200
2 = 38400
3 = 578600
4 = 115200
0 = None
1 = Odd
2 = Even
0 = MM/DD/YY
1 = DD/MM/YY
2 = YY/MM/DD
0 = Always On
0 = Off
1 = On
0 = Off
1 = On
Used for F3 and F2 alarms
0 = Off
1 = On
Used for F3 and F2
deviations
0 = Off
1 = On
0 = cc/min
1 = l/min
2 = gal/min
0 = psi
1 = bar
2 = MPa
0 = cc
1 = l
2 = gal
0 = cc
1 = l
2 = gal
Used for MF advisory
Scaled as 1% = 65536
Active when 403094 = 0
3A6948A