To prevent Fire and Explosion, when using a Pro
Control 1KE Plus system in a hazardous location,
use a power supply with an IS barrier.
Power supply modules are ordered separately and
depend on whether your ProControl 1KE Plus system
is being used in a non-hazardous or hazardous
location. Additional considerations for each location
are discussed below.
Note
Power supply modules come with power
cables to connect to port 3 of the ProControl
1KE Plus ADCM user interface.
Non - - - Hazardous
Hazardous Locations
Locations
Non
Non
Hazardous
Locations
Order power supply 16V680 (AC/DC Converter) and
choose a power cord below.
Note
The 16V680 AC/DC Converter has an
IEC-320-C13 female input power connection
and a 68 in. (1.7 m) output cord to connect
to port 3 of the ProControl 1KE Plus ADCM
user interface.
• 245202 – 120 in. (3 m) North American 120 VAC
power cord.
• 116281 – 72 in. (1.8 m) extension (Male x Female)
IEC-320 cord.
• 242001 – 8 in. (0.2 m) IEC-320 European-style
power cord.
• 242005 – 8 in. (0.2 m) IEC-320 ANZ-style power
cord.
3A6948A
Guide
Guide
Hazardous Locations
Hazardous
Hazardous
To determine the correct power supply module,
answer these questions:
If you answered "Yes" to any of these questions,
order the 26C724 IS G-Barrier Power Supply Module.
If you answered "No" to all of these questions, you
may consider ordering the 16M167 Single IS Barrier
Power Supply Module.
ProControl 1KE Plus Models
Locations
Locations
Yes
Yes
Yes
No
No
No
Will you be using ProControl 1KE
Plus models 25B296–25B299 for
fluid and atomizing air control?
Would you potentially want to
upgrade a ProControl 1KE Plus
model in the future for use with fluid
and atomizing air control?
Do you need to power more than
one ProControl 1KE Plus unit, or
want the ability to power up to
three units from one power supply
module in the future?
Will your application ever require
greater than 50 psi (3.4 bar) of
fluid pressure at the outlet of the
ProControl 1KE Plus for units with
the standard Graco 24C375 1:1
Low Flow Regulator;
or,
for units using an alternate
air-operated fluid regulator, will your
application ever require greater
than 50 psi (3.4 bar) of air pilot
pressure to the fluid regulator?
Note
Up to three total ProControl 1KE Plus models
of any configuration can be powered by
a single G-Barrier. If you are adding a
ProControl 1KE Plus model to an existing
26C724 G-Barrier Power Supply Module,
order a power cable kit 19Y499 (50 ft (16 m))
or 19Y502 (100 ft (32m)).
Note
The 16M167 Single IS Barrier Power Supply
Module has power limitations. It cannot be
used on ProControl 1KE Plus models that
require greater than 50 psi (3.4 bar) of fluid
pressure (50 psi (4.4 bar) of pilot air pressure
for alternate air-operated fluid regulator use),
or on units that control fluid and atomizing air.