Appendix A - Modbus Variable Map
Address
Address Description
Address
Description
Description
403080
Pressure PID Kp
403082
Pressure PID Ki
403084
Pressure PID Kd
403086
Fill mode fluid drive
percentage
403088
Fill mode drive
timeout
403090
Flush mode fluid
drive percentage
403092
Flush mode drive
timeout
403094
Operational Mode
403096
Pressure maximum
setpoint limit
403098
Pressure minimum
setpoint limit
403100
Pressure Control
internal setpoint
403102
Unused
403104
Unused
403106
Flow PID Kp
403108
Flow PID Ki
403110
Flow PID Kd
403112
Flow Control
internal setpoint
403114
Unused
403116
Unused
403118
Unused
403120
Unused
403122
Unused
403124
Unused
403126
Unused
403128
Unused
403130
Unused
403132
Unused
403134
Unused
403136
Unused
403138
Unused
403140
Unused
403142
Unused
403144
Unused
403146
Unused
403148
Unused
86
Permissions
Permissions
Permissions
Units
Units
Units
Read/Write
Value
Read/Write
Value
Read/Write
Value
Read/Write
Value
Read/Write
Value
Read/Write
Value
Read/Write
Value
Read/Write
Value
Read/Write
bar
Read/Write
bar
Read/Write
bar
Read/Write
Read/Write
Read/Write
Value
Read/Write
Value
Read/Write
Value
Read/Write
cc/min
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Low
Low
Low
High
High
High
0
999
0
999
0
999
0
100
0
500
0
100
0
500
0
3
0
0x63E667
0
0x63E667
0
0x63E667
0
999
0
999
0
999
0
32-bit
Notes
Notes
Notes
0 = Monitor
1 = Pressure Control
2 = Flow Control
3 = Current
Scaled as 1 bar = 65536
Scaled as 1 bar = 65536
Scaled as 1 bar = 65536
3A6948A