In Standby Mode, the atomizing air and the fluid
pressure pilot regulators are set to zero (0). The
flow meter remains operational, and the system
will show fluid flow and accumulated fluid volume.
Residual pressure may be in the system depending
on the nature of the air and fluid regulators, material
properties, and other variances.
When the system is first powered up, the type of
fluid in the system is unknown. This is indicated with
checkerboard pattern on the gun. After a fluid Fill
process, the gun is shown as black to indicate that it
is loaded with sprayable material. After a fluid Flush
process, the gun is shown as white to indicate that
it is loaded with solvent.
Table
Table 2 2 2 Standby
Table
Standby Mode
Standby
Mode Run
Mode
Description
Description
Description
Examples
Examples
Examples
Standby after
power-up with an
unknown fluid
Standby with
paint loaded
Standby with
solvent loaded
3A6948A
Run Screens
Run
Screens
Screens
The following icons are available on the Run Screen
in Standby Mode:
Enter the screen.
Atomizing air regulator
Flow rate target (Closed Loop Flow
Control Mode)
% pilot air pressure target to fluid
regulator
Pressure target (Closed Loop Pressure
Mode)
Current (mA) setpoint to pilot air control
Current fluid pressure
Standby Mode – Unknown fluid in system
Standby Mode – System filled with
sprayable material
Standby Mode – System filled with
solvent
Move between Run Screens.