Setup Screen 12: Flush Mode; Setup Screen 13: Control Method - Graco ProControl 1KE Plus Instructions-Parts List Manual

Models for management of fluid and air
Table of Contents

Advertisement

Setup Screens
Setup Screen
Screen 12:
12: Flush
Setup
Setup
Screen
12:
Use this screen to set up the parameters for Flush
Mode. When set, the Minimum Flush Volume is
checked against the amount of material that flowed
during the Flush process. The "SP" Minimum Flush
Volume alarm is set if this isn't achieved.
Enter the screen to set or change
preferences.
Press to activate a field for editing or
to accept the highlighted selection on
a menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Set fluid regulator to a percent open.
The first box displays the remaining
time when a Flush Mode is active.
Set a flush duration time.
Minimum Flush Volume. Set zero to
disable this feature
Exit data editing.
Move between Setup Screens, fields
on a screen, or to increment/decrement
the digits when editing number fields.
52
Flush Mode
Mode
Flush
Mode
Key
Key
Key
Setup Screen
Screen 13:
13: Control
Setup
Setup
Screen
13:
Use this screen to set the system control method.
See
Control Method Considerations, page
more information.
Table 14
14 Setup
Setup Screen
Screen 13
Table
Table
14
Setup
Screen
Description
Examples
Description
Description
Examples
Examples
With control
method
selected
With selection
menu open
Enter the screen to set or change
preferences.
Press to activate a field for editing or
to accept the highlighted selection on
a menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Control Method selection.
Scaled percentage of the 4mA to 20mA
range of the control valve.
Direct pressure setpoint for closed-loop
control.
Direct flow rate setpoint for closed-loop
control.
Direct milliamp output selection to the
control valve.
Exit data editing.
Move between Setup Screens, fields
on a screen, or to increment/decrement
the digits when editing number fields.
Control Method
Method
Control
Method
32, for
13
13
Key
Key
Key
3A6948A