Deviations and Advisories

Deviations and
and Advisories
Deviations
Deviations
and
There are three types of events that can occur.
Events are indicated on the display by alternately
flashing between the event code and the event icon.
• Alarms, indicated by
Fluid and atomizing air pressures are set to zero,
and the system is returned to Standby mode.
• Deviations, indicated by
will not stop the system.
• Advisories, indicated by
system.
If multiple events are active, the display will cycle
through the events at the highest priority level. For
instance, if F3, P3, and MF are all active, the display
will cycle between only F3 and P3.
Alarm
Alarm Log
Alarm
Log Logic:
Log
Logic:
Logic: (Available for Flow and Pressure
Alarms only) If Alarm Auto Clear is enabled, the
system will not log the same alarm twice. For
example, if the system goes back and forth between
Code
Code
Code
Icon
Icon
Icon
Summary
Summary
Summary
F3
High Flow
F2
Low Flow
P3
High
Pressure
P2
Low
Pressure
QT
Dose
Time
56
Advisories
Advisories
, will stop the system.
, require attention but
, will not stop the
Deviations and
Deviations
Deviations
Description
Description
Description
Selectable event level. Active
when the flow rate is higher than
the user-set maximum for one
second.
Selectable event level. Active
when the flow rate is lower than the
user-set minimum for a variable
time depending on operating
conditions.
Selectable event level. Active
when the fluid pressure is higher
than the user-set maximum for one
second.
Selectable event level. Active
when the fluid pressure is lower
than the user-set minimum for one
second.
Alarm only. Active when the gun
trigger is activated but no fluid flow
is detected.
low flow (F2) and normal, the system will log this
error only once to keep the log from filling up before
the operator corrects the condition.
If Alarm Auto Clear is not enabled, each alarm will
log only once if the operator corrects the condition
and then clears the alarm. The alarm will log twice
if the operator clears the alarm before correcting the
condition.
Note
In Pressure Control or Flow Control mode,
the setpoint target is not modified to keep
system within the F2 and F3 range configured
in
Setup Screen 5: Flow Rate, page
or within the P2 and P3 range configured
in
Setup Screen 7: Pressure, page
The alarms conditions are monitored
independently of the control system.
The following table explains the error type that is
associated with each error code and icon. Press
to clear alarm after the cause has been addressed.
and Advisories
Advisories
and
Advisories
Adjust flow rate, maximum
flow limit, or disable alarm
(
Setup Screen 5: Flow Rate, page
Press
clear until the flow rate is within limits.
Adjust flow rate, minimum
flow limit, or disable alarm
(
Setup Screen 5: Flow Rate, page
Press
clear until the flow rate is within limits.
Adjust pressure, maximum pres-
sure limit, or disable alarm
(
Setup Screen 7: Pressure, page
Press
clear until the pressure is within limits.
Adjust pressure, minimum pres-
sure limit, or disable alarm
(
Setup Screen 7: Pressure, page
Press
clear until the pressure is within limits.
Determine cause of fluid flow stoppage.
46,
48.
Solution
Solution
Solution
to clear alarm. The alarm will not
to clear alarm. The alarm will not
to clear alarm. The alarm will not
to clear alarm. The alarm will not
46).
46).
48).
48).
3A6948A