glid Flight Mode menu
1) Press the Navigation Pad 56 to highlight MIXING, then press the ENTER key to display the MIXING menu. The AI 4 RU1
sub-menu will be highlighted by default.
2) Press the Navigation Pad 6 to highlight MT 4 EL, then press the
ENTER key to display the MT 4 EL menu. The cursor will default to
COMMON>COM.
3) Press the YES/+ or NO/- keys to choose the desired COM or SEP
option as described previously.
4) Press the Navigation Pad 6 to highlight MT 4 EL>0%.
5) Press the YES/+ or NO/- keys to change the Motor 4 Elevator mixing
percentage value.
The Motor 4 Elevator mixing percentage value is a ratio of elevator travel to motor travel. Regardless if the motor function
is assigned to a non-proportional switch or to a control stick, or an Auxiliary Lever, the Motor 4 Elevator mixing percentage
value programmed will result in only half the programmed movement. For example, when the Motor 4 Elevator mixing percentage
value is set to 20%, the elevator will travel 1/10th the amount that the motor travels. Even if the motor is assigned to a control
stick or an Auxiliary Lever, the elevator will jump to the Motor 4 Elevator mixing percentage value programmed, as if it
were assigned to a non-proportional switch.
MT 4 EL setting range is -100% to 100%. The default setting is 0%. When the percentage value is increased from 0% to 100%,
elevator travel will increase in one direction in relation to motor travel. When the percentage value is decreased from
0% to -100%, elevator travel will increase in the opposite direction in relation to motor travel.
Camber to Elevator Mixing
The Camber to Elevator Mixing function allows you to mix a percentage of elevator control with Camber or Reflex control.
The Camber to Elevator Mixing function is typically used to reduce pitch changes associated with adding Camber or Reflex.
For example, the aircraft may pitch up when Camber is added. You can mix down elevator to help eliminate the pitch
change. The amount and the direction that the elevator moves when Camber or Reflex is added is adjusted by changing
the Camber 4 Elevator mixing percentage value either positive or negative. An Input and Output display, along with a
graph, help with programming visualization.
IMPORTANT The Camber to Elevator Mixing function must be assigned to a Switch Position Number before it can be
Activated. For more information, see page 45.
Function Output (O)
Page 144
Stick Input (I)
150%
100%
0%
100%
150%
Point Positions