1.4 Greasing-up

Maintenace Interval
Annually
CAUTION
When applying grease, prevent foreign object being mixed into grease.
The above Maintenance Interval is given as a standard interval, Maintenace Interval is subject to
NOTE
change depending on the usage environment of the machine.
Supplier
Shin-Etsu Chemical Co., Ltd.
CAUTION
If the grease attached on your hand or body, wipe off with dry cloth or waste cloth. Afterwards rinse
with soup and flowing water. In case of grease is dropped on the floor, wipe it with a waste cloth then
spread sand and wipe it off thoroughly.
Step1:
Grease up the scan ball screw and linear guide.
Step2:
Remove the five M4 cross recessed head screws and remove the top of scan table.
Items
Scan Ball Screw
With a dry soft cloth or paper, wipe off any old grease or stains.
Linear Guide
Apply fresh grease.Wipe off any excess grease with a dry and
Spring Guide
soft cloth or paper.
Table 1-2
Model
G-30M
Table 1-3
Applied Grease
Linear Guide
FFFure 1-17
M4 cross recessed head screw
FFFure 1-18
Procedures
Greasing-up
Flammable Attribution
Extremely Low Risk
Scan Ball Screw
Greasing-up 1
Greasing-up 2
Maintenance Manual
Exchange Volume
20 cc