1.3 Cleaning Optical System

The following points are required regular maintenance.
WARNING
Regarding the cleaning optical system, if the cleaning procedure is not operated in an appropriate
way, it could cause trouble such as image misalignment. If a regular maintenance is required, please
contact Saki Corporation. If you require to do the maintenance on your own, we provide specialized
jigs(tools) and fare-paying training. Please contact Saki Corporation for details.
Maintenance Interval
Weekly
Every 6 months
CAUTION
The maintenance interval above is a standard period, however it is subject to change depending on the
machine usage environment. Make sure that the power of the machine is turned off before starting.
(*1) Chemicals should not be used for cleaning.
(*2) Do not use other chemicals.
CAUTION
Cleaning the dusts of air intake and intake fan regularly.
Items
ShadFnF Sheet
Light Control Film
Camera Lens
Telecentric Lens
Mirror
DFffuser
Table 1-1
Intake Fan
FFFure 1-2
Cleaning the Air Intake and Intake Fan
Wipe off any dirt gently with a dry and soft cloth or paper. (*1)
Wipe off any dirt gently with a dry and soft cloth or paper.
In case of heavy dirt, soak a dry and soft cloth or paper in
ethanol or glass cleaner and wipe them out. (*2)
Cleaning Method
Air Intake