SAKI BF-Sirius Manual page 29

Table of Contents

Advertisement

The following describes the items of Auto Mode Setup dialog(Figure 3-30).
Item
Inspect
Current Board Num.
Clear the Amount
Limit Count
Edit NG Components
Monitor Mode
Make NG files
Lot Number
Print out to journal
printer
Table 3-3
(*1) This does not include the numbers of the PCB inspected in Manual Mode.
NOTE
(*2) If you wish to continue the setup in limit count after auto running is stoppled, press
  Clear the Amount Fn Auto Mode Setup dialog to reset Current Board Num., and
  reload the image.
(*3) Check the Print Barcode of Time Information, inspection time / date will be printed
  together with NG information.
All the PCBs will be inspected automatically.
This item must be checked at any time.
This shows the number of inspected PCBs in Auto Mode. (*1)
Set 0(zero) to this item if inspection data changed.
Resets Current Board Num..
Press Clear the Amount Ff Current Board Num. reaches Limit Count.
The dialog shown in Figure 3-33 appears.
OK
Current Board Num. is reset to 0(zero).
Cancel Current Board Num. remains unchanged.
Set the maximum number of PCBs to be inspected in Auto Mode.
Inspection will be stopped when the number of inspected PCBs reaches the
specified number. After the operation stops, the dialog shown in Figure 3-34
appears. Press OK to return to the inspection window. (*2)
Not available.
Not available.
Save the as many NG data as the preset number of PCBs in the same file.
If you enter the number of NG data and check this item, the making interval of the
NG file can be set.
(e.g. If enter 25, it can save NG data equivalent to the number of magazine rack
in one file.)
Set the lot number of the PCB. The inspection result is stored in the folder whose
name has and automatically created lot number, so which can be useful for
controlling the inspection results by lot.
If optional journal printer is connected to AOI and this box is checked, the NG
information can be printed onto the roll paper. (*3)
Explanation on Each Item for
Description
FFFure 3-33
Clear the Amount
FFFure 3-34
Limit Count
Auto Mode Setup
Operation Manual
BF-Sirius
I-23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents