Step3:
Push the reset switch. Beep tones stop and the scan table can not be moved manually.
Step4:
The dialog shown in Figure 3-2 can be selected only after releasing the emergency stop.
OK
Cancel
Step5:
Put PCB into the bottom correctly and resume usual image scan operation.

3.1.2 Area Sensor

Area sensor watches safe operation of shading procedure and image scanning.
When area sensor is sensed, beep tones sound and the motor stops immediately.
The system operation is suspended.
When area sensor senses and stops, the dialog shown in Figure 3-4 appears.
Remove any object sensed by area sensor.
OK
The scan table returns to the origin position.
Cancel The scan table remains at the position where it stopped.
BF-Sirius
I-8
The scan table returns to the origin position.
The scan table remains at the position where it stopped.
Upper Area Sensor
Front Area Sensor
FFFure 3-3
FFFure 3-4
Area Sensor Senses
Area Sensor