Table 38: General module / channel parameters

Parameter
Diagnosis
Substitute value
Channel x (x = 0...7)
*)
Default setting
1)
A substitute value unequal 0 can only be selected using firmware versions as from FW17 for
750-833(/0xx-000) or FW18 for 750-333(/0xx-000)
Manual
Version 1.0.0
Value
The fieldbus coupler signals a diagnosis if an undervoltage of I/O
module's field side power supply arises. This kind of module diagnosis is
referred to channel 0.
*)
0 (disabled)
1 (enabled)
1)
*)
-32767 ... 0
... 32767 If, in the event of a PROFIBUS DP fault, the
WAGO-I/O-SYSTEM 750
750-597 8AO 0-10V/±10V DC
Explanation
Diagnostics reported by the I/O module do not
lead to the signaling of a diagnosis by the
fieldbus coupler.
Diagnostics reported by the I/O module lead to
the signaling of a diagnosis by the fieldbus
coupler.
switching of substitute values is enabled within
fieldbus coupler's parameterization, this value
is transmitted to the periphery in the event of a
fault.