2. Overview and connenction technology I/O modules

2.3.1 Fitting the sub-bases

Festo P.BE-CPX-EA-EN en 0112NH
Please note
Handle all modules and components of the CPX terminal
with great care. Please note especially the following:
Screws must be fitted accurately (otherwise threads will
be damaged).
Screws must be tightened only by hand. Place screws so
that the self-cutting threads can be used.
The specified torques must be observed.
Screw connections must be fitted free of offset and
mechanical tension.
Check the seals for damage (IP65).
Connecting surfaces must be clean (sealing effect, avoid
leakage and contact faults).
The screw connection between the sub-base and the mani-
fold is designed for at least 10 fitting/removal cycles under
observance of the instructions.
Observe also the installation instructions supplied with
modules and components ordered at a later stage.
CPX terminals are supplied from the factory completely fitted.
It may be necessary to fit or remove the sub-bases for the
following reasons:
for replacing the connections.
to simplify fitting the sensor plugs or cables.
It may be necessary to fit or remove the electronic modules
for the following reasons:
for modifying the function of the I/O module (e.g.
CPX-8DE instead of CPX-4DE).
for replacing defective electronic modules.