1. Pneumatic interfaces
1-10
Setting of the DIL switch
DIL switch setting
Midi/Maxi
CPA
Switches
8: reserved
7: reserved
6: reserved
5: reserved
4: OFF/OPEN
3: OFF/OPEN
2: OFF/OPEN
1: ON/CLOSED
8: reserved
7: reserved
6: reserved
5: reserved
4: OFF/OPEN
3: OFF/OPEN
2: ON/CLOSED
1: as desired
8: reserved
7: reserved
6: reserved
5: reserved
4: OFF/OPEN
3: ON/CLOSED
2: as desired
1: as desired
Setting
8: reserved
not
7: reserved
permitted
6: reserved
5: reserved
4: ON
3: as desired
2: as desired
1: as desired
1)
Depending both on the field bus node and on the equipment
fitted on the CPX, see following note.
2)
Additionally reserved output addresses remain unused..
Tab. 1/2: DIL switch setting
Assigned addresses
8 outputs for valves
16 outputs for valves
24 outputs for valves
(factory setting for
1)
CPA
)
– With CPA: only 22 can
2)
be used
32 outputs for valves
(factory setting for
1)
Midi/Maxi
)
– With Midi/Maxi: only
2)
26 can be used
Festo P.BE-CPX-EA-EN en 0112NH