2. Overview and connenction technology I/O modules
Festo P.BE-CPX-EA-EN en 0112NH
Sub-base CPX-AB-4-M12-8POL
Please note
In order that completely fitted modules with sub-base
CPX-AB-4-M12-8POL comply with protection class IP65:
Use cable type KM12-8GD8GS-2-PU from Festo for
connecting the cylinder-valve combination type DNCV
or other sensors and actuators (see Appendix A.8).
Tighten the union nuts of the plugs by hand.
Seal unused sockets with protective caps type ISK-M12
(Accessories).
Screening plate type CPX-AB-S-4-12
A screening plate is in preparation for sub-base CPX-
AB-4-M12-8POL. The electromagnetic compatibility can be
improved with screening plates, e.g. in environments heavily
subjected to interference or for analogue signals.