2. Overview and connenction technology I/O modules
Screwdriver, blade
1
2.5 x 0.4 mm
2
Unlocking opening
(inside)
3
Cables
4
Terminal opening
for inserting the
conductors (outside)
5
Terminal strips
Fig. 2/3: Wiring the terminal strip
2-12
2. When the terminal is unlocked you can insert or pull out
the ends of the cable through the opening.
3. Remove the screwdriver from the unlocking opening. The
cable will then be securely locked.
1
3
4
2
Sub-base CPX-AB-1-SUB-BU-25POL
The completely fitted sub-base CPX-AB-1-SUB-BU-25POL
complies with protection class IP20.
In order that sub-base CPX-AB-1-SUB-BU-25POL complies
with protection class IP65/IP67, use plug type
SD-SUB-D-ST25 from Festo.
When fitting the plug onto the sub-base, observe the
maximum tightening torque of 0.5 Nm.
5
Festo P.BE-CPX-EA-EN en 0112NH