Festo CPX Electronic Manual page 55

Hide thumbs Also See for CPX:
Table of Contents

Advertisement

2. Overview and connenction technology I/O modules
Fitting
Festo P.BE-CPX-EA-EN en 0112NH
Fit the modules as follows (see Fig. 2/5):
Please note
Please observe the instructions on combining I/O
modules and sub-bases in section 2.2.2.
Please observe the instructions on combining and
arranging I/O modules on the CPX terminal in the CPX
system manual.
Only in cases where the electronic module has been
removed:
Place the electronic module in the manifold sub-base.
Make sure that the appropriate grooves with the contact
terminals on the bottom of the electronic module lie
above the contact rails. Then push the electronic module
carefully and without tilting as far as possible into the
manifold sub-base.
Fitting the sub-base:
1. Align the sub-base over the manifold sub-base with the
electronic module. Make sure that the plug connectors of
the sub-base lie exactly over the connectors of the elec-
tronic module. Then push the sub-base carefully and
without tilting onto the manifold sub-base.
2. Tighten the screws only by hand. Place the screws so that
the self-cutting threads can be used.
Tighten the screws in diagonally opposite sequence with
a Torx screwdriver size T10 with 0.9...1.1 Nm.
2-19