2. Grasp the molded horizontal handles on the power supply module and pull the
3. Align the replacement module with the empty chassis bay.
4. Slide the replacement power supply module into the bay until the module is secured
5. Secure the power supply module to the chassis with two thumbscrews at the corners
Replacing the SCA SCSI drive cage and fused power cable
Due to the potential of an over-current condition, Avaya provides a retrofit SCSI power cable
kit for the N0029330 power cable. The kit comprises an improved SCSI power cable, product
label, and retrofit procedure.
Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
power supply module free from the chassis (see B in the preceding diagram).
by its connector. Use some force, if necessary.
of the power supply faceplate.
Result: The power supply LED illuminates green.
Note:
If the LED does not illuminate, remove and reinstall the power supply with more
force. If this does not work, contact your Avaya customer support representative.
Replacing the SCA SCSI drive cage and fused power cable
December 2010
81