Maintaining the Pentium III SBC card
Figure 38: SBC card connectors and jumpers.
To replace the SBC cardDANGER
1.
2. Disconnect the power cord.
3. Remove the top cover.
4. Disconnect and label all cables from the SBC card. See SBC card connectors and
5. Disconnect and label cables from the SBC card faceplate.
6. Loosen and remove the screw that is securing the SBC card.
7. Loosen and remove the screw located at the top of the card faceplate.
8. Loosen the SBC and pull it up from the backplane.
140
Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
Danger:
Risk of explosion
The SBC has a lithium battery installed. If you are discarding the SBC, dispose
of used batteries according to the manufacturer's instructions. Replacement of
the battery with an incorrect type also raises the risk of an explosion.
Power down the server.
jumpers. Refer to
Figure 37: SBC card location
on page 138 to locate the SBC card.