RealPresence Collaboration Server (RMX) 4000 Components and Components Replacement

Component Slot Allocation

On the RMX 4000, components have been assigned dedicated slots as defined in the following table. Slot
numbers are located on both the front and rear of the RMX 4000.
RMX 4000 Slot Numbering
Slot ID/No.
Card/Component
1-4
MPMx/MPMRx Cards
5
Fabric Switch Module
(FSM 4000)
6
CPU 2
7
Logo Panel
8
CTNL 4000 unit (CPU 1)
9-11
AC Power Supply
12
Fan Drawer
13-16
RTM ISDN/RTM LAN
17
RTM IP 4000
18
Blank Panel
19-21
Power Modules
Polycom, Inc.
Requirement
Mandatory: At least one MPMx/MPMRx card is required. Each media
card also requires either an RTM ISDN or an RTM LAN card.
Mandatory
Not Available (NA)
Not Available (NA)
Mandatory
An RMX with AC power has three power supplies installed. A 3rd
power supply is redundant (n+1).
Note: Not used with DC powered systems. DC powered systems
receive Direct Current from the DC PEM.
Mandatory
Either an RTM ISDN or an RTM LAN card is mandatory in
combination with a Media card. The RTM ISDN/RTM LAN board must
be inserted in a slot opposite any MPMx/MPMRx card.
Mandatory
Not Available (NA)
Mandatory:
With AC power, three power supplies are installed, with the 3rd
redundant.
With DC power, two power supplies are installed with the 2nd
redundant. The center slot (#20) on the rear of the RMX 4000 is
disabled and is fitted with blank panel.
Note: Protective bonding conductor size is 14AWG (1.5mm) within
the Power Entry Model.