1-3 Current Consumption Check

The following table shows the specified value of current consumption in each status.
Measurement condition
: Product status, camera auto mode(AF OFF), LCD ON (Approx. 0.1A each smaller in case of CVF)
Preset voltage
: 7.4V
POWER SW
MODE
CAMERA
REC PAUSE
REC
VCR
STOP
PLAY
POWER OFF
MVX250i E, MVX200i E, MVX200 E
Current consumption (A)
0.43
0.47
0.29
0.37
0.6 (mA)
4