1. Disassembling and Reassembling - (1)

Notes

(1) When replacing the flat cable with a new one, allow it to remain folded the same as the original part.
(2) The flat cable has a contact orientation to be engaged with the connector. Refer to the instructions in the disassembly procedure
diagram and interconnection diagram for boards.
• Lateral engaging connector
( The instructions are given in the disassembly proce-
dure diagram and board interconnection diagram.)
: Contacts are positioned downward. (board side)
∗ : Contacts are positioned upward.
Metal contact (Pins' face down)
:
Metal contact (Pins' face up)
:
(3) To secure screws, apply the Three Bond 1401B (CY9-8011-000)
(4) If any part to be replaced has UL tape attached on it, be sure to reattach UL tape at the same position in reassembling.
(5) Use the new type connector (MAIN P.C.B. CN102) as illustrated.
FPC
Metal
contact
Lock
(6) For replacing the fuse mounted on the MAIN P.C.B., it is required to remove the CVF unit.
MVX250i E, MVX200i E, MVX200 E
• Lengthwise engaging connector
( The instructions are given in the disassembly proce-
dure diagram and board interconnection diagram.)
Indicated by → Arrowheads indicate the contacts, and the
shafts indicate the noncontacts.
Metal contact
Metal
contact
Unlock
1
DISASSEMBLING
Metal contact
FPC