Mechanical Error Indication; Mechanical Error Normal Mode - Canon MVX200 E Service Manual

Table of Contents

Advertisement

4-2 Mechanical Error Indication

<Outline>
(1) On occurrence of a mechanical error, the conditions of the error can be checked in the service mode. (Normal indication mode and
analysis mode available)
(2) In the normal indication mode of the mechanical error, two types of indications appear on the service mode initial screen: the data
indication retained only by the main battery and the error history data indication backed up by LITHIUM 3V.
(3) The data backed up by the LITHIUM 3V can be reset by the STEP-1 operation shown below.
ST EP
PROCEDURE
1
1) Make setting shown at right.
2) Execute ST ORE. (Press PAUSE.)

4-2-1 Mechanical Error Normal Mode

MONIT OR
CS
Function ADDR MODE
0
08
0008
ST
RD
Relevant errors are highlighted in purple.
Fig. 13
9
MVX250i E, MVX200i E, MVX200 E
SERVICE MODE · ADJUSTMENT
Microcomputer operation
DT
00
Completion of backup data resetting
E
: TAPE END
B
: TAPE TOP
D
: DRUM ERROR
C
: CAPSTAN ERROR
S
: S-REEL ERROR
T
: T- REEL ERROR
L
: LOADING MTR ERROR
D
: DEW ERROR

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvx200i eMvx250i e

Table of Contents