Setting; Using The Extension Connectors - Canon MVX200 E Service Manual

Table of Contents

Advertisement

2. Setting

(1) Adjustments other than DMC-III : Perform adjustments in the product state.
(2) Tracking adjustment (DMC-III) and Envelope check : Perform them with the Setting A.
(3) Adjustments related to DMC-III other than Tracking adjustment, tape path system check and tape path system cleaning : Perform
them with the Setting B.

2-1 Using the Extension Connectors

(1) Attach the two extension connectors (DY9-1395-000) to the
extension flexible cable (DY9-1390-000)
Important
Secure the two connectors with tape as shown in
the figure. (When removing the extension con-
nector assembly from the main unit after use, the
connector coupling may be detached in some
cases. If the connector located on the main unit
side comes off, it becomes impossible to remove
it from the main unit. To prevent this, secure the
connectors with tape beforehand.)
(2) Detach the blindfold sheet.
(3) Connect the extension connectors to the CN2900.
<Signals used>
Signal
Pin No.
Designation
2
EVF HD
3
GND
15
SWP
19
PBRF
Fig. 2
Signal
Pin No.
Designation
21
EVF R
22
EVF COM
23
EVF G
24
EVF B
DY9-1390-000
DY9-1395-000
DY9-1395-000
Secure with tape.
MVX250i E, MVX200i E, MVX200 E
BLINDFOLD SHEET
2
SERVICE MODE · ADJUSTMENT
Fig. 1
Fig. 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mvx200i eMvx250i e

Table of Contents