5-8-3 Automatic Adjustment of Reel FG
MODE
Stop without VTR cassette
Procedure)
(1) Carry out reel FG adjustment according to the following table.
ST EP PROCEDURE
1
1) Make the setting shown at right.
2) Perform storing.
(press the PAUSE button.)
5-8-4 Battery Voltage Drop Adjustment
MODE
During camera recording in product condition (AF : OFF, LCD PANEL : ON)
SPEC.
Power supply voltage: 5.85 ± 0.02 [V]
Note)
(1) Perform the adjustment after 4sec of recording start.
(2) In step 1 - 2), after completion of storing, "ST" remains indicated or "WR" is indicated momentarily and then "ST" is indicated
again without returning to "RD". Be sure to check in step 2 that the adjustment has been completed.
Procedure)
(1) Under the above condition, set a power supply voltage to 5.85 ± 0.02[V].
(2) Referring to the table shown below, carry out battery voltage drop adjustment.
ST EP PROCEDURE
BAT T ERY VOLT AGE DROP.
1
1) Make the setting shown at right.
2) Perform storing.
(press the PAUSE button.)
2
Check if the value of DT is updated on DT 2 during ST ORE.
5-8-5 Flash Memory Writing
SPEC.
Memory data writing
Procedure)
(1) Write adjustment data (5-8-1 to 4) into the flash memory according the table shown below.
ST EP PROCEDURE
1
1) Make the setting shown at right.
2) Perform storing.
(press the PAUSE button.)
MONIT OR
CS Function MD ADDR DT
0
08
ST
0007
--
WR
↑
↑
↑
↑
RD
MONIT OR
CS Function MD ADDR DT
1
08
ST
0001
--
RD
↑
↑
↑
↑
MONIT OR
CS Function MD ADDR DT
0
08
ST
0081
--
RD
↑
↑
↑
↑
35
MVX250i E, MVX200i E, MVX200 E
SERVICE MODE · ADJUSTMENT
Microcomputer operation
Automatic adjustment is in progress.
Automatic adjustment is completed.
Microcomputer operation
Adjustment is completed.
Microcomputer operation
Preparation for flash memory updating.
Execution of flash memory updating.