Canon MVX200 E Service Manual page 120

Table of Contents

Advertisement

<Note on Reassembling>
(1) Attach the Core Cushion to the position indicated in the figure below.
(2) Attach the Shielding Rubber to the PM Shield as illustrated below.
(3) Secure the flexible cable by attaching the UL Tape to the position indicated in the figure below.
Note on Reassembling (1)
Top end
of IC
End of P.C.B.
Core Cushion
Note on Reassembling (2)
When attaching the Shielding Rubber, push it
to the part A of the Recorder Holder so that
the MAIN P.C.B. will not be unseated.
Part A
PM1 Shield
MAIN P.C.B.
Note on Reassembling (3)
MAIN P.C.B.
Attachment
reference
The UL tape shall not protrude from
the outline of the Motor.
It is not allowed to attach
the Shielding Rubber in
an overlaying form.
PM1 Shield
Shielding Rubber
Fig. 14
17
MVX250i E, MVX200i E, MVX200 E
UL Tape (9 × 20)
Motor
Take care not to let the Shielding Rubber
be sandwiched between the MAIN P.C.B.
and the MAIN Holder.
MAIN P.C.B.
Shielding Rubber
PM Shield
Attachment reference
DISASSEMBLING
MAIN P.C.B.
PM2 Shield
Recorder
Holder