5-2 Mechanical Error Indications

<Generals>
(1) When the camcorder is stopped upon detection of a mechanical error, the POWER LED indicator blinks and the message "EJECT
CASSETTE"appears on screen. At this step, the error condition can be checked in the service mode.
(2) A mechanical error indication is given in either one of the following two manners: indication of data held only by the main battery,
and indication of data backed up by the Lithium 3V. Referring to the table shown below, select an indication mode.
(3) Data backed up by the Lithium 3V can be reset at step 3.
ST EP
PROCEDURE
MECH. ERROR
1
1) Make setting shown at right.
2
1) Make setting shown at right.
3
1) Make setting shown at right.
2) Press the ST ORE key.
<Indication of error data held only by the main battery>
PG B K MD
7
R e l e v a n t e r r o r i n d i c a t i o n i s h i g h l i g h t e d .
<Indication of error data backed up by Lithium 3V>
PG B K MD
7
R elevant e rro r in d ic a ti o n is h ig h l i g h te d .
     MONIT OR
PG
BK
MD ADDR DT
7
2
RD
7
2
RD
7
2
WR
RD
ADDR
D
T
S T
-
2 R D
- - 0 1
-
E B
D
C
S
T L D
Fig. 3-6
ADDR
D
T
S T
2 R D
- - 0 2
-
-
* *
D
C
S
T L D
Fig. 3-7
CAHPTER 3. INFORMATION FOR REPAIR · SERVICE HINTS
Microcomputer operation
ST
--01
--
Error data held only in the POWER-ON
state is indicated.
--02
--
Error data backed up by the EEPROM is
indicated.
--02
00
*
Completion of backup data resetting
E
: T A P E E N D
B
: T A P E T O P
D
: D R U M E R R O R
: C A P S T A N E R R O R
C
S
: S - R E E L E R R O R
T
: T - R E E L E R R O R
L
: L O A D I N G M T R E R R O R
: D E W E R R O R
D
D
: D R U M E R R O R
C
: C A P S T A N E R R O R
S
: S - R E E L E R R O R
T
: T - R E E L E R R O R
: L O A D I N G M T R E R R O R
L
D
: D E W E R R O R
3-6
ELURA20 MC A, ELURA10 A