Figure 79
1. Bed support
2. Cylinder barrel
Lowering the Tank Assembly
1.
When you are ready to lower the tank assembly,
remove the bed support from the cylinder and
insert it into the brackets on the back of the
ROPS panel.
CAUTION
Do not try to lower the tank assembly
with the bed safety support on the
cylinder.
2.
Retract the lift cylinders to carefully lower the
tank to the frame.
3.
Install the 2 hold down bolts and fasteners to
secure the tank assembly.
4.
Fold the boom extensions rearward to the
extended position.
5.
Use the
-
BOOM
CONTROL
boom extensions to the transport position.
g009164
3. Bed
switches to raise the
Lubrication
Greasing the Sprayer
System
Service Interval: Every 50 hours
Every 100 hours
Lubricate all bearings and bushings after every
100 hours or once a year, whichever occurs first.
Grease Type: Number 2 general-purpose,
lithium-based grease
1.
Wipe the grease fitting clean so that foreign
matter cannot be forced into the bearing or
bushing.
2.
Pump grease into the bearing or bushing.
3.
Wipe off the excess grease.
1. Pump
61
Figure 80
2. Grease point
g018934