Figure 96
1. Bypass fitting
Cleaning the Manifold Valve
1.
Position the valve stem so that it is in the closed
position (B of
Figure
Figure 97
1. Valve open
2.
Remove the 2 endcap-fitting assembies from
each end of the manifold body
Figure
99).
2. Section valve manifold
97).
2. Valve closed
(Figure 98
and
g028239
1. Stem retainer
2. Valve stem
3. Stem port
4. Stem-capture retainer
5. Endcap fitting
6. Endcap seal O-ring (0.796
inch / 0.139 inch)
g027562
70
Figure 98
Agitation Valve Manifold
7. Back seating O-ring (0.676
inch / 0.07 inch)
8. Valve-seat ring
9. Mainfold body
10. Ball valve
11. Endcap-fitting assembly
g028243