R8C/11 Group
19.3 Clock Generation Circuit
19.3.1 Oscillation Stop Detection Function
Since the oscillation stop detection function cannot be used if the main clock frequency is below
2MHz, set the OCD1 to OCD0 bits to "00
19.3.2 Oscillation Circuit Constants
Ask the maker of the oscillator to specify the best oscillation circuit constants on your system.
Rev.1.20
Jan 27, 2006
REJ09B0062-0120
page 190 of 204
" (oscillation stop detection function disabled).
2
19. Usage Notes