Final tasks for replacing an S8500/B/C server using the blank hard drive (continued)
Task
39
RSA only: Log into the RSA
card
40
RSA only: Set a timeout
value
41
RSA only: Set the loader
watchdog timeout
42
RSA only: Log off and
disconnect from the RSA

Re-using the original hard drive

Using this procedure means that you are re-using the original hard drive.
Final tasks for replacing an S8500/B/C server reusing the
original hard drive
Task
1
Connect laptop to the
server
2
Log onto the Maintenance
Web Interface
3
Verify date and time
4
Ping the connections on the
server
Description
Open a browser on your laptop. Type 192.11.13.6 and
press Enter to log into the RSA.
Note: Use the initial installation craft login and the initial
RSA password.
On the RSA welcome screen, on the Inactive session
timeout value field, select no timeout and click
Continue. This allows 60 minutes of inactivity before
disconnecting.
Under ASM Control, click System Settings. Scroll down
to the Server Timeouts section, and in the Loader
watchdog field, select 5.0 (minutes) and click Save.
Click Log Off. Once you are logged off, disconnect from
the services port on the RSA.
Description
Connect to the services port on the back of the server.
Open a browser on your laptop. Type 192.11.13.6
and press Enter to log onto the Maintenance Web
Interface.
Under Server, click Server Date/Time. Make changes
as necessary.
Under Diagnostics, click Ping. Ensure that all
administered connections respond.
03-300529 Issue 4 January 2008
Hard drive
6 of 6
1 of 2
21