Replacing The Samp On The Avaya S8500B Server; Powering Down The S8500B Server - Avaya S8500 Series Job Aids For Field Replacements

Hide thumbs Also See for S8500 Series:
Table of Contents

Advertisement

Job Aid: Replacing the SAMP on the Avaya S8500 Series server

Replacing the SAMP on the Avaya S8500B server

The S8500B server (IBM x306 server) is equipped with the Server Availability Management
Processor™ (SAMP) remote maintenance board (Material ID 700330814).
These S8500B SAMP replacement topics are covered in this section:

Powering down the S8500B server

l
Removing the S8500B server from the rack
l
Removing the cover of the S8500B server
l
Removing and replacing the SAMP card on the S8500B server
l
Replacing the cover of the S8500B server
l
Reconnecting cables on the S8500B server
l
Powering up the S8500B server
l
Reconfiguring the SAMP card on the S8500B server
l
S8500B server connections
l
S8500B services access and logins
l
Powering down the S8500B server
Note:
Wear an antistatic wrist ground strap whenever handling the server or its
Note:
components. Connect the strap to an approved ground, such as an unpainted
metal surface. See the job aid titled Approved Grounds for more information.
To power down the S8500B server:
1. From the Maintenance Web Interface, click Shutdown Server.
The Shutdown Server page displays.
2. Select Delayed.
3. Click on the Shutdown button at the bottom of the page.
The Shutdown This Server page displays the shutdown indicators.
4. Wait until the server powers down before proceeding. Check for the absence of disk activity
on the front panel to determine whether the server has powered down.