Avaya S8500 Series Job Aids For Field Replacements page 29

Hide thumbs Also See for S8500 Series:
Table of Contents

Advertisement

Removing the RSA from the replacement S8500 server
To remove the RSA from the replacement S8500 server.
1. Remove the cover of the server. See
2. Remove the RSA from the replacement server. See
S8500 server
Installing the original RSA in the replacement S8500 server
To install the original RSA in the replacement S8500 server.
1. Carefully grasp the original RSA by the top edges or upper corners, component side facing
up, and align it with the PCI-X slot 1 opening in the replacement server. Press the RSA
firmly into the riser card connector. See
Supervisor Adapter (S8500 only)
!
CAUTION:
Make sure the RSA card is completely and correctly seated in the riser card
CAUTION:
connector before you turn on the S8500 server. Incomplete insertion might cause
damage to the system board or RSA card.
2. Connect the ribbon cable to the system-management connector located on the back of the
card.
3. Replace the adapter support bracket lining up the tabs on each side of the bracket and the
screw holes on the riser card connector.
4. Align the riser card with the connector and the tabs on the adapter support bracket with the
provided holes and press the riser card firmly into the connector.
5. Finger-tighten the captive screw to the right of the slot.
6. If you are re-using the optional dual network interface, go to
interface card (S8500)
If you are not using the dual network interface, go to
replacement S8500 server
on page 27.
on page 28.
below.
on page 32.
Removing the cover of the S8500 server
Removing the RSA from the failed
Figure 3: Removing and replacing the Remote
Replacing the cover on the
03-300529 Issue 4 January 2008
Replacing the S8500 server
on page 23.
Reusing the optional network
29